Teledyne Marine Sanitation System NALL User Manual

Browse online or download User Manual for Unknown Teledyne Marine Sanitation System NALL. Teledyne Marine Sanitation System NALL User's Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - HASTINGS

INSTRUCTION MANUAL MODEL NALL MASS FLOWMETERS TELEDYNE HASTINGS INSTRUMENTS ISO 9001CERTIFIED

Page 2 - Manual Print History

Manual 111-082010_Nall Mass Flowmeters Page 10 of 23 4.4.3 Electrical Zero Check Turn the power supply “ON” and allow the flowmeter 30 minutes to w

Page 3

Manual 111-082010_Nall Mass Flowmeters Page 11 of 23 5.0 USING THE FLOWMETER USING THE HASTINGS LINEAR MASS FLOWMETER 5.1 Warm-Up Time: When the fl

Page 4

Manual 111-082010_Nall Mass Flowmeters Page 12 of 23 Actual flow = meter reading X (KHe) = 50 SCCM X 1.382

Page 5 - 1.0 General Information

Manual 111-082010_Nall Mass Flowmeters Page 13 of 23 Example: (A) What is the output sensitivity of HS-1KS? (B) What is the flow rate for a 2

Page 6 - 2.0 OPERATING PRINCIPLE

Manual 111-082010_Nall Mass Flowmeters Page 14 of 23 6.0 PRESSURE EFFECTS 6.1 Standard Transducers: The Hastings Linear Mass Flowmeter can measure m

Page 7 - 3.0 RECEIVING AND INSPECTION

Manual 111-082010_Nall Mass Flowmeters Page 15 of 23 7.0 TEMPERATURE EFFECTS 7.1 Ambient Temperatures: 7.1.1 Transducer In order to maintain the ac

Page 8 - 4.1 TRANSDUCER

Manual 111-082010_Nall Mass Flowmeters Page 16 of 23 8.0 DIFFERENTIAL PRESSURE 8.1 TYPICAL PRESSURE DROPS The differential pressure drop (DP) across

Page 9 - 4.4 POWER SUPPLY:

Manual 111-082010_Nall Mass Flowmeters Page 17 of 23 8.2.2 Decrease in Line Pressure The relationship stated in Section 8.2.1 also shows that DP in

Page 10 - 4.4.3 Electrical Zero Check

Manual 111-082010_Nall Mass Flowmeters Page 18 of 23 9.0 Calibration 9.1 CALIBRATION PROCEDURES The Hastings Mass Flowmeter has been carefully inspe

Page 11 - 5.0 USING THE FLOWMETER

Manual 111-082010_Nall Mass Flowmeters Page 19 of 23 TRANSDUCER MILLIVOLT TEST +5 VDC OUTPUT BIAS METER GAIN TRMS AC TEST

Page 12 - 5.6 Output Signal:

Manual 111-082010_Nall Mass Flowmeters Page 2 of 23 Manual Print History The print history shown below lists the printing dates of all revisions and

Page 13 - 5.9 Over-range:

Manual 111-082010_Nall Mass Flowmeters Page 20 of 23 10.0 Maintenance 10.1 Transducers: 10.1.1 Cleaning With proper care in installing and use, th

Page 14 - 6.0 PRESSURE EFFECTS

Manual 111-082010_Nall Mass Flowmeters Page 21 of 23 11.0 Accessories OPTIONS AND ACCESSORIES 11.1 Double Point Relay Flowmeter/Alarm (DNALL-P): T

Page 15 - 7.0 TEMPERATURE EFFECTS

Manual 111-082010_Nall Mass Flowmeters Page 22 of 23 a) What is the sensitivity of the totalizer? b) What is the total flow indicated by the 13,50

Page 16 - 8.0 DIFFERENTIAL PRESSURE

Manual 111-082010_Nall Mass Flowmeters Page 23 of 23 12.0 Warranty and Repair 12.1 Warranty Repair Policy Hastings Instruments warrants this produ

Page 17

Manual 111-082010_Nall Mass Flowmeters Page 3 of 23 Table of Contents 1.0 GENERAL INFORMATION...

Page 18 - 9.0 Calibration

Manual 111-082010_Nall Mass Flowmeters Page 4 of 23 11.6 SPECIFICATIONS...

Page 19

Manual 111-082010_Nall Mass Flowmeters Page 5 of 23 1.0 General Information 1.1 Features: Hastings Linear Mass Flowmeters are designed to accurately

Page 20 - 10.0 Maintenance

Manual 111-082010_Nall Mass Flowmeters Page 6 of 23 2.0 OPERATING PRINCIPLE 2.1 Operating Principle Hastings Linear Mass Flowmeters operate on a uni

Page 21 - 11.0 Accessories

Manual 111-082010_Nall Mass Flowmeters Page 7 of 23 3.0 RECEIVING AND INSPECTION 3.1 Initial Inspection: Carefully unpack the Hastings Linear Mass F

Page 22

Manual 111-082010_Nall Mass Flowmeters Page 8 of 23 4.0 INSTALLATION INSTRUCTIONS. 4.1 TRANSDUCER 4.1.1 Orientation of the Transducer The transduce

Page 23 - 12.0 Warranty and Repair

Manual 111-082010_Nall Mass Flowmeters Page 9 of 23 The use of O-ring seal connectors on the transducers with female threads is often more convenien