Teledyne 9110TH - Nitrogen Oxides Analyzer User Manual

Browse online or download User Manual for Equipment Teledyne 9110TH - Nitrogen Oxides Analyzer. Teledyne 9110TH - Nitrogen Oxides Analyzer User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 335
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews

Summary of Contents

Page 1 - Nitrogen Oxides Analyzer

Teledyne Analytical Instruments INSTRUCTION MANUAL Model 9110TH Nitrogen Oxides Analyzer TELEDYNE ELECTRONIC TECHNOLOGIES Analytical Instrume

Page 3 - Model 9110TH NOx Analyzer

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 80 4.8. SETUP  RNGE: RANGE UNITS AND DILUTION CONFIGURATION

Page 4 - Range Mode

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 81 4.8.2. DILUTION RATIO The dilution ratio is a software op

Page 5

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 82 4.9. SETUP  PASS: PASSWORD FEATURE The 9110TH/M provides

Page 6

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 83 Example: If all passwords are enabled, the following menu

Page 7 - SAFETY MESSAGES

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 84 4.10. SETUP  CLK: SETTING THE INTERNAL TIME-OF-DAY CLOCK

Page 8 - CONSIGNES DE SÉCURITÉ

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 85 In order to compensate for CPU clocks which run fast or sl

Page 9

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 86 4.11. SETUP  MORE  COMM: SETTING UP THE ANALYSER’S COMM

Page 10

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 87 4.11.3. COMMUNICATION MODES, BAUD RATE AND PORT TESTING U

Page 11 - ABOUT THIS MANUAL

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 88 Press the following buttons to select a communication mod

Page 12

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 89 4.11.3.2. COM Port Baud Rate To select the baud rate of on

Page 13 - TABLE OF CONTENTS

Manual Information Model 9110TH NOx Analyzer Teledyne Analytical Instruments xi ABOUT THIS MANUAL This manual describes operation, specificati

Page 14

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 90 4.11.3.3. COM Port Testing The serial ports can be tested

Page 15

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 91 4.11.4. ANALYZER ID Each type of TAI analyzer is configure

Page 16 - LIST OF FIGURES

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 92 4.11.5. RS-232 COM PORT CABLE CONNECTIONS In its default

Page 17

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 93 Figure 4-6: CPU COM1 & COM2 Connector Pin-Outs for R

Page 18 - LIST OF TABLES

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 94 4.11.6. RS-485 CONFIGURATION OF COM2 Opting to use RS-48

Page 19 - LIST OF APPENDICES

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 95 4.11.7.1. Configuring Ethernet Communication Using DHCP 1.

Page 20

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 96 Table 4-13: LAN/Internet Configuration Properties PROPER

Page 21 - 1.3. USING THIS MANUAL

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 97 4.11.7.2. Configuring Ethernet Communication Manually (Sta

Page 22 - 1.4. OPTIONS

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 98 Internet Configuration Button Functions BUTTON

Page 23 - Description/Notes Reference

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 99 4.11.7.3. Changing the Analyzer’s HOSTNAME The HOSTNAME

Page 24

Model 9110TH NOx Analyzer Manual Information Teledyne Analytical Instruments xii This page intentionally left blank.

Page 25 -  290 cm³/min total flow

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 100 4.11.8. USB PORT SETUP The analyzer can be operated thro

Page 26 - 2.2.2. EMC

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 101 5. In the instrument’s SETUP>MORE>COMM>COM2 men

Page 27 - 3. GETTING STARTED

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 102 4.11.9. MULTIDROP RS-232 SET UP When the RS-232 Multidro

Page 28 - 3.3. 9110TH/M LAYOUT

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 103 Figure 4-8: Jumper and Cables for Multidrop Mode Note

Page 29

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 104 Analyzer Analyzer Analyzer Last Analyzer Female DB9M

Page 30

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 105 4.11.10. MODBUS SETUP The following set of instructions a

Page 31

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 106 Example Read/Write Definition window: Example Connect

Page 32

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 107 4.12. SETUP  MORE  VARS: INTERNAL VARIABLES (VARS) The

Page 33

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 108 To access and navigate the VARS menu, use the following

Page 34 - 3.4. ELECTRICAL CONNECTIONS

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 109 4.12.1. SETTING THE GAS MEASUREMENT MODE In its standard

Page 35

Table of Contents Model 9110TH NOx Analyzer Teledyne Analytical Instruments xiii TABLE OF CONTENTS Information About the Specific Configurati

Page 36 - On analyzers with O

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 110 4.13. SETUP  MORE  DIAG: DIAGNOSTICS MENU A series of

Page 37

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 111 4.13.1. ACCESSING THE DIAGNOSTIC FEATURES To access the D

Page 38

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 112 To enter the signal I/O test mode, press: SAMPLE

Page 39

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 113 4.13.3. ANALOG OUTPUT STEP TEST This test can be used to

Page 40

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 114 4.13.4. ANALOG OUTPUTS AND REPORTING RANGES 4.13.4.1. An

Page 41 - LARM OUT

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 115 Additionally A1, A2 andA3 may be equipped with optional

Page 42

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 116 selects which physical range is in effect based on the a

Page 43

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 117 4.13.5. ANALOG I/O CONFIGURATION 4.13.5.1. The Analog I/O

Page 44 - 3.5. PNEUMATIC CONNECTIONS

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 118 5. Set the reporting range scale for the data type chos

Page 45

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 119 4.13.5.2. Analog Output Signal Type and Range Selection T

Page 46

Model 9110TH NOx Analyzer Table of Contents Teledyne Analytical Instruments xiv 4.8.1. Range Units ...

Page 47 - (High Concentration)

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 120 4.13.5.3. Turning the Analog Output Over-Range Feature O

Page 48

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 121 To Turn the over-range feature on or off, press: From the

Page 49

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 122 around the zero point. This can be achieved in the 9110

Page 50 - INSTRUMENT CHASSIS

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 123 4.13.5.5. Assigning a DAS Parameter to an Analog Output C

Page 51

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 124 The available gas concentration DAS parameters for outpu

Page 52 - O3 FLOW

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 125 To assign a DAS parameter to a specific analog output cha

Page 53

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 126 4.13.5.8. Setting the Reporting Range Scale for an Analo

Page 54

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 127 To set the reporting range for an analog output, press: E

Page 55

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 128 4.13.5.9. Setting Data Update Rate for an Analog Output

Page 56

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 129 To change the update rate for an individual analog output

Page 57

Table of Contents Model 9110TH NOx Analyzer Teledyne Analytical Instruments xv 7.2.1. 9110TH Internal Gas Flow Diagrams ...

Page 58

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 130 4.13.5.10. Turning an Analog Output On or Off Each outpu

Page 59 - Sensor Option 65A

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 131 4.13.6. ANALOG OUTPUT CALIBRATION Analog calibration need

Page 60

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 132 4.13.6.1. Automatic Analog Output Calibration To calibra

Page 61 - 3.6. INITIAL OPERATION

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 133 To initiate an automatic calibration for an individual ou

Page 62

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 134 4.13.6.2. Manual Calibration of Analog Output Configured

Page 63 - 3.7. CALIBRATION

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 135 To manually adjust the signal levels of an analog output

Page 64 - STEP 1 - Set Units:

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 136  As before, adjustment of the output is performed unti

Page 65 - STEP 2 - Dilution Ratio:

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 137 Table 4-25: Current Loop Output Calibration with Resist

Page 66 - STEP 3 – Set NO

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 138 4.13.6.4. AIN Calibration This is the sub-menu calibrate

Page 67

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 139  offset (volts)  engineering units to be represented

Page 68 - SAMPLE GAS

Model 9110TH NOx Analyzer Table of Contents Teledyne Analytical Instruments xvi 8.3.8. Ozone Supply Air Filter ...

Page 69 - Calibration Method

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 140 4.13.7. OTHER DIAG MENU FUNCTIONS 4.13.7.1. Display Sequ

Page 70 - EXIT 3 times to return

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 141 The default settings for this feature are: Table 4-27: 9

Page 71 - ZERO/SPAN CALIBRATION :

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 142 To delete an entry in the display value list, press:

Page 72

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 143 4.13.7.2. Optic Test The optic test function tests the re

Page 73 - 4. OPERATING INSTRUCTIONS

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 144 4.13.7.3. Electrical Test The electrical test function c

Page 74 - 4.2. SAMPLE MODE

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 145 4.13.7.4. Ozone Generator Override This feature allows th

Page 75 - A4:NXCNC2=100%

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 146 To access this feature press the following menu sequence

Page 76 - A1:NXCNC1=100 PPM

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 147 4.13.7.5. Flow Calibration The flow calibration allows th

Page 77

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 148 4.14. SETUP – ALRM: USING THE OPTIONAL GAS CONCENTRATION

Page 78 - 4.4. SETUP MODE

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 149 4.15. Remote Operation 4.15.1. REMOTE OPERATION USING THE

Page 79 - CONFIGURATION INFORMATION

Table of Contents Model 9110TH NOx Analyzer Teledyne Analytical Instruments xvii Figure 3-19: 9110TH – Internal Pneumatics with Ambient Zero-

Page 80 - PRIMARY SETUP MENU

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 150 Table 4-29: Status Output Pin Assignments CONNECTOR PIN

Page 81 - DAS STATUS

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 151 There are two methods to activate control inputs. The in

Page 82 - 4.7.1. DAS STRUCTURE

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 152 4.15.2.2. Help Commands in Terminal Mode Table 4-31: Te

Page 83

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 153 4.15.2.4. Data Types Data types consist of integers, hexa

Page 84 - 4.7.2. DEFAULT DAS CHANNELS

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 154 possible messages, and this section for information on c

Page 85

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 155 To change this setting press: SETUP X.X SECONDARY

Page 86 - SAMPLES

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 156 To initialize the modem press: Select which COM Port i

Page 87

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 157 LOGON 940331 940331 is the default password. To change t

Page 88

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 158 Figure 4-18: APICOM Remote Control Program Interface A

Page 89 - 4.7.2.3. Trigger Events

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 159 only respond to commands from the host computer and only

Page 90 - Press SET> key until…

Model 9110TH NOx Analyzer Table of Contents Teledyne Analytical Instruments xviii Figure 8-4: Reaction Cell During the AutoZero Cycle ...

Page 91 - (see previous section)

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 160 The first step in configuring the 9110TH/M to operate o

Page 92

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 161 and COM2, the TYPE selection affects both ports. 4.15.4.4

Page 93

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 162 4.15.4.5. Hessen Protocol Gas ID Since the 9110TH/M meas

Page 94

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 163 4.15.4.6. Setting Hessen Protocol Status Flags TAI implem

Page 95 - 4.7.2.7. Number of Records

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 164 To assign or reset the status flag bit assignments, pres

Page 96

Calibration Procedures Model 9110TH NOx Analyzer Teledyne Analytical Instruments 165 5. CALIBRATION PROCEDURES This section describes calibrat

Page 97 - Press SET> ke y until…

Model 9110TH NOx Analyzer Calibration Procedures Teledyne Analytical Instruments 166 5.2. CALIBRATION PREPARATIONS 5.2.1. REQUIRED EQUIPMENT

Page 98 - 4.7.2.12. HOLDOFF Feature

Calibration Procedures Model 9110TH NOx Analyzer Teledyne Analytical Instruments 167 5.2.3. SPAN CALIBRATION GAS STANDARDS & TRACEABILITY

Page 99

Model 9110TH NOx Analyzer Calibration Procedures Teledyne Analytical Instruments 168 5.2.4. DATA RECORDING DEVICES A strip chart recorder, d

Page 100 - CONFIGURATION

Calibration Procedures Model 9110TH NOx Analyzer Teledyne Analytical Instruments 169 5.2.5.1. Determining / Updating the NO2 Converter Efficie

Page 101 - 4.8.2. DILUTION RATIO

Table of Contents Model 9110TH NOx Analyzer Teledyne Analytical Instruments xix Table 4-21: DIAG - Analog I/O Functions ...

Page 102 - Toggle this

Model 9110TH NOx Analyzer Calibration Procedures Teledyne Analytical Instruments 170 STEP TWO: Set the expected NO2 span gas concentration:

Page 103

Calibration Procedures Model 9110TH NOx Analyzer Teledyne Analytical Instruments 171 STEP THREE Activate NO2 measurement stability function. S

Page 104 - PRIMARY SETUP MENU

Model 9110TH NOx Analyzer Calibration Procedures Teledyne Analytical Instruments 172 STEP FOUR: Perform the converter efficiency calculatio

Page 105 - SECONDARY SETUP MENU

Calibration Procedures Model 9110TH NOx Analyzer Teledyne Analytical Instruments 173 5.3. MANUAL CALIBRATION The following section describes

Page 106 - COMMUNICATION PORTS

Model 9110TH NOx Analyzer Calibration Procedures Teledyne Analytical Instruments 174 VENT here if input is pressurized Source ofSAMPLE Gas P

Page 107 - ID DESCRIPTION

Calibration Procedures Model 9110TH NOx Analyzer Teledyne Analytical Instruments 175 STEP TWO: Set Expected NO and NOX Span Gas Concentration

Page 108 - PRIMARY SETUP MENU

Model 9110TH NOx Analyzer Calibration Procedures Teledyne Analytical Instruments 176 STEP THREE: Perform Zero/Span Calibration: Press ENTR

Page 109 - 4.11.3.2. COM Port Baud Rate

Calibration Procedures Model 9110TH NOx Analyzer Teledyne Analytical Instruments 177 5.4. CALIBRATION CHECKS Informal calibration checks, whic

Page 110 - 4.11.3.3. COM Port Testing

Model 9110TH NOx Analyzer Calibration Procedures Teledyne Analytical Instruments 178 5.5. MANUAL CALIBRATION WITH ZERO/SPAN VALVES Zero and

Page 111 - 4.11.4. ANALYZER ID

Calibration Procedures Model 9110TH NOx Analyzer Teledyne Analytical Instruments 179 STEP TWO: Set Expected NO and NOX Span Gas Concentration

Page 112

Model 9110TH NOx Analyzer Teledyne Analytical Instruments ii Copyright © 2013 Teledyne Analytical Instruments All Rights Reserved. No part of

Page 113

Model 9110TH NOx Analyzer Table of Contents Teledyne Analytical Instruments xx This page intentionally left blank.

Page 114 - LED FUNCTION

Model 9110TH NOx Analyzer Calibration Procedures Teledyne Analytical Instruments 180 STEP THREE: Perform Zero/Span Calibration: Press ENTR

Page 115 - SETUP X.X DHCP: ON

Calibration Procedures Model 9110TH NOx Analyzer Teledyne Analytical Instruments 181 5.6. CALIBRATION CHECKS WITH ZERO/SPAN VALVES Zero and sp

Page 116

Model 9110TH NOx Analyzer Calibration Procedures Teledyne Analytical Instruments 182 5.7. CALIBRATION WITH REMOTE CONTACT CLOSURES Contact c

Page 117

Calibration Procedures Model 9110TH NOx Analyzer Teledyne Analytical Instruments 183 5.8. AUTOMATIC CALIBRATION (AUTOCAL) The AutoCal feature

Page 118 - Network Administrator

Model 9110TH NOx Analyzer Calibration Procedures Teledyne Analytical Instruments 184 The following example sets sequence #2 to carry out a z

Page 119 - BUTTON FUNCTION

Calibration Procedures Model 9110TH NOx Analyzer Teledyne Analytical Instruments 185 To program the sample sequence shown above, follow this f

Page 120 - 4.11.8. USB PORT SETUP

Model 9110TH NOx Analyzer Calibration Procedures Teledyne Analytical Instruments 186 5.9. CALIBRATION QUALITY ANALYSIS After completing one

Page 121

Instrument Maintenance Model 9110TH NOx Analyzer Teledyne Analytical Instruments 187 6. INSTRUMENT MAINTENANCE Predictive diagnostic functions

Page 122

Model 9110TH NOx Analyzer Instrument Maintenance Teledyne Analytical Instruments 188 This page intentionally left blank.

Page 123

Instrument Maintenance Model 9110TH NOx Analyzer Teledyne Analytical Instruments 189 Table 6-1: 9110TH/M Preventive Maintenance Schedule ITEM

Page 124 - NOTES:

Introduction Model 9110TH NOx Analyzer Teledyne Analytical Instruments 1 1. INTRODUCTION, FEATURES, AND OPTIONS 1.1. OVERVIEW The Models 9110T

Page 125 - 4.11.10. MODBUS SETUP

Model 9110TH NOx Analyzer Instrument Maintenance Teledyne Analytical Instruments 190 This page intentionally left blank.

Page 126

Instrument Maintenance Model 9110TH NOx Analyzer Teledyne Analytical Instruments 191 6.3. PREDICTIVE DIAGNOSTICS The analyzer’s test function

Page 127 - and slope of the NO

Model 9110TH NOx Analyzer Instrument Maintenance Teledyne Analytical Instruments 192 and tweezers. We recommend not to touch any part of th

Page 128 - PRIMARY SETUP MENU

Instrument Maintenance Model 9110TH NOx Analyzer Teledyne Analytical Instruments 193 6.4.2. CHANGING THE O3 DRYER PARTICULATE FILTER The air

Page 129 - . It can also

Model 9110TH NOx Analyzer Instrument Maintenance Teledyne Analytical Instruments 194 6.4.3. MAINTAINING THE EXTERNAL SAMPLE PUMP 6.4.3.1. Re

Page 130

Instrument Maintenance Model 9110TH NOx Analyzer Teledyne Analytical Instruments 195 6.4.4. CHANGING THE NO2 CONVERTER The NO2 converter is l

Page 131 - 4.13.2. SIGNAL I/O

Model 9110TH NOx Analyzer Instrument Maintenance Teledyne Analytical Instruments 196 9. Re-attach the tube fittings to the converter and re

Page 132

Instrument Maintenance Model 9110TH NOx Analyzer Teledyne Analytical Instruments 197 Figure 6-4: Reaction Cell Assembly 4. The reaction ce

Page 133

Model 9110TH NOx Analyzer Instrument Maintenance Teledyne Analytical Instruments 198 10. After cleaning, the analyzer span response may drop

Page 134 - 0-20 mA current loop

Instrument Maintenance Model 9110TH NOx Analyzer Teledyne Analytical Instruments 199 5. Take out the components of the assembly: a spring, a

Page 135

Model 9110TH NOx Analyzer Introduction Teledyne Analytical Instruments 2 1.4. OPTIONS Option Option Number Description/Notes Reference Pumps

Page 136

Model 9110TH NOx Analyzer Instrument Maintenance Teledyne Analytical Instruments 200 This page intentionally left blank.

Page 137

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 201 7. TROUBLESHOOTING & REPAIR This section conta

Page 138 - AIO Configuration Submenu

Model 9110TH NOx Analyzer Troubleshooting & Repair Teledyne Analytical Instruments 202  Suspect a leak first! Technical Support data i

Page 139

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 203 The analyzer also issues an alert via the serial

Page 140

Model 9110TH NOx Analyzer Troubleshooting & Repair Teledyne Analytical Instruments 204 SAMPLE SYSTEM RESET NOX = XXX.

Page 141

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 205 Table 7-1: Test Functions - Possible Causes for O

Page 142

Model 9110TH NOx Analyzer Troubleshooting & Repair Teledyne Analytical Instruments 206 SAMPLE A1:NXCNC1=100PPM NOX=XXX.X

Page 143 - NXCNC1 NOCNC1 N2CNC1 NXCNC2

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 207 7.1.4. STATUS LED’S Several color-coded, light-emi

Page 144

Model 9110TH NOx Analyzer Troubleshooting & Repair Teledyne Analytical Instruments 208 7.1.4.3. Relay Board and Status LEDs The most imp

Page 145 - Use these buttons to move

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 209 Table 7-2: Relay Board Status LEDs LED COLOR FUN

Page 146

Introduction Model 9110TH NOx Analyzer Teledyne Analytical Instruments 3 Option Option Number Description/Notes Reference Communication Cables

Page 147 - Use these

Model 9110TH NOx Analyzer Troubleshooting & Repair Teledyne Analytical Instruments 210 SAMPLE A1:NXCNC1=100PPM NOX=XXX.X

Page 148

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 211 7.2.1. 9110TH INTERNAL GAS FLOW DIAGRAMS Figure

Page 149

Model 9110TH NOx Analyzer Troubleshooting & Repair Teledyne Analytical Instruments 212 Figure 7-6: 9110TH – Internal Gas Flow with Am

Page 150

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 213 Figure 7-7: 9110TH – Internal Gas Flow with O

Page 151

Model 9110TH NOx Analyzer Troubleshooting & Repair Teledyne Analytical Instruments 214 7.2.2. 9110TM INTERNAL GAS FLOW DIAGRAMS VACUUM

Page 152

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 215 Figure 7-9: 9110TM – Internal Gas Flow with A

Page 153

Model 9110TH NOx Analyzer Troubleshooting & Repair Teledyne Analytical Instruments 216 VACUUM PRESSURE SENSORSAMPLE PRESSURE SENSORO3 FL

Page 154 - (1 count)

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 217 If the pump is operating but the unit reports a XX

Page 155 - AUTO-CAL is

Model 9110TH NOx Analyzer Troubleshooting & Repair Teledyne Analytical Instruments 218  Check the actual flow rate through the ozone d

Page 156 - See Table 3-2 for

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 219 re-calibrate the flow electronically using the pro

Page 157 - 100% 5.0 V 5.0 V

Model 9110TH NOx Analyzer Introduction Teledyne Analytical Instruments 4 This page intentionally left blank.

Page 158

Model 9110TH NOx Analyzer Troubleshooting & Repair Teledyne Analytical Instruments 220  A corruption of the Auto-zero filter may also

Page 159 - Units and whether to display

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 221  Check for disconnected cables to the sensor mod

Page 160

Model 9110TH NOx Analyzer Troubleshooting & Repair Teledyne Analytical Instruments 222  Verify that the expected concentration is set

Page 161 - sensor option is installed

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 223  The standard gases may be mislabeled as to type

Page 162

Model 9110TH NOx Analyzer Troubleshooting & Repair Teledyne Analytical Instruments 224  NO2 impurities in the NO calibration gas. NO

Page 163 - 4.13.7.2. Optic Test

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 225  Wrong materials in contact with sample - use gl

Page 164 - 4.13.7.3. Electrical Test

Model 9110TH NOx Analyzer Troubleshooting & Repair Teledyne Analytical Instruments 226  A dirty reaction cell can cause high AutoZero

Page 165

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 227 surfaces. Do not exceed 15 psi when pressurizing t

Page 166

Model 9110TH NOx Analyzer Troubleshooting & Repair Teledyne Analytical Instruments 228  Attach the outlet port of a flow meter to the

Page 167 - 4.13.7.5. Flow Calibration

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 229 Functions of the Relay PCA include:  handling

Page 168 - Disabled 300 ppm 401.6 mg/m

Specifications Model 9110TH NOx Analyzer Teledyne Analytical Instruments 5 2. SPECIFICATIONS AND APPROVALS 2.1. 9110TH/M OPERATING SPECIFICATI

Page 169 - 4.15. Remote Operation

Model 9110TH NOx Analyzer Troubleshooting & Repair Teledyne Analytical Instruments 230 110 VAC /115 VAC 220 VAC /240 VAC 1 2 3 4 5 67

Page 170 - 4.15.1.2. Control Inputs

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 231 7.5.4.2. AC Configuration – Standard Heaters (JP2)

Page 171 - 4.15.2. REMOTE OPERATION

Model 9110TH NOx Analyzer Troubleshooting & Repair Teledyne Analytical Instruments 232 7.5.4.3. AC Configuration –Heaters for Option Pac

Page 172 - 4.15.2.3. Command Syntax

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 233 7.5.5. DC POWER SUPPLY TEST POINTS Table 7-6: DC

Page 173 - 4.15.2.5. Status Reporting

Model 9110TH NOx Analyzer Troubleshooting & Repair Teledyne Analytical Instruments 234 7.5.7. TOUCH SCREEN INTERFACE Verify the function

Page 174

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 235 7.5.10. MOTHERBOARD 7.5.10.1. A/D functions A basi

Page 175

Model 9110TH NOx Analyzer Troubleshooting & Repair Teledyne Analytical Instruments 236 7.5.10.3. Status Outputs The procedure below can

Page 176

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 237 7.5.10.4. Control Inputs The control input bits ca

Page 177

Model 9110TH NOx Analyzer Troubleshooting & Repair Teledyne Analytical Instruments 238 7.5.12. RS-232 COMMUNICATION 7.5.12.1. General RS

Page 178

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 239  Use the RS-232 test function to send “w” charac

Page 179 - Parameter Standard Hessen

Model 9110TH NOx Analyzer Specifications Teledyne Analytical Instruments 6 2.2. APPROVALS AND CERTIFICATIONS The TAI Nitrogen Oxides Analyze

Page 180

Model 9110TH NOx Analyzer Troubleshooting & Repair Teledyne Analytical Instruments 240 Divide the displayed HVPS voltage by 10 and test

Page 181

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 241 7.5.16.2. Sample Pressure Measure the voltage acro

Page 182 - GAS DEFAULT HESSEN GAS ID

Model 9110TH NOx Analyzer Troubleshooting & Repair Teledyne Analytical Instruments 242  Temperature is reported properly but heater do

Page 183

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 243 To avoid this problem, we recommend the use of a

Page 184 - 4.15.4.7. Instrument ID Code

Model 9110TH NOx Analyzer Troubleshooting & Repair Teledyne Analytical Instruments 244 7.5.20. PMT TEMPERATURE PMT temperature should be

Page 185 - 5. CALIBRATION PROCEDURES

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 245 7.6. REPAIR PROCEDURES This section contains some

Page 186 - 5.2.2. ZERO AIR

Model 9110TH NOx Analyzer Troubleshooting & Repair Teledyne Analytical Instruments 246 7.6.2. O3 GENERATOR REPLACEMENT The ozone generat

Page 187 - 5.2.3.1. Traceability

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 247 6. Attach the replacement dryer to the mounting b

Page 188 - CONVERSION EFFICIENCY (CE)

Model 9110TH NOx Analyzer Troubleshooting & Repair Teledyne Analytical Instruments 248 9. Set the HVPS coarse adjustment switch to the

Page 189 - Instrument

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 249 7.6.5. REPLACING THE PMT, HVPS OR TEC The photo mu

Page 190 - span gas concentration:

Getting Started Model 9110TH NOx Analyzer Teledyne Analytical Instruments 7 3. GETTING STARTED 3.1. UNPACKING AND INITIAL SETUP CAUTION THE 9

Page 191 - Activate NO

Model 9110TH NOx Analyzer Troubleshooting & Repair Teledyne Analytical Instruments 250 Figure 7-18: 9110TH/M Sensor Assembly Figure 7

Page 192

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 251 9. Discard the plastic screws and replace with ne

Page 193 - 5.3. MANUAL CALIBRATION

Model 9110TH NOx Analyzer Troubleshooting & Repair Teledyne Analytical Instruments 252 7.7. REMOVING / REPLACING THE RELAY PCA FROM THE

Page 194

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 253 7.8. FREQUENTLY ASKED QUESTIONS The following list

Page 195

Model 9110TH NOx Analyzer Troubleshooting & Repair Teledyne Analytical Instruments 254 QUESTION ANSWER Can I use the DAS system in place

Page 196

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 255 This page intentionally left blank.

Page 197 - 5.4. CALIBRATION CHECKS

Model 9110TH NOx Analyzer Principles of Operation Teledyne Analytical Instruments 256 8. PRINCIPLES OF OPERATION The 9110TH/M Nitrogen Oxides

Page 198

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 257 νhNONO +2*2→ (Equation 9-2) All things being const

Page 199

Model 9110TH NOx Analyzer Principles of Operation Teledyne Analytical Instruments 258 8.1.2. NOX AND NO2 DETERMINATION The only gas that is t

Page 200

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 259 8.2. CHEMILUMINESCENCE DETECTION 8.2.1. THE PHOTO

Page 201

Model 9110TH NOx Analyzer Getting Started Teledyne Analytical Instruments 8  b. Remove the 2 screws fastening the top cover to the unit (o

Page 202

Model 9110TH NOx Analyzer Principles of Operation Teledyne Analytical Instruments 260 8.2.3. AUTO ZERO Inherent in the operation of any PMT i

Page 203

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 261 8.2.4. MEASUREMENT INTERFERENCES It should be d th

Page 204

Model 9110TH NOx Analyzer Principles of Operation Teledyne Analytical Instruments 262 Table 8-1: List of Interferents GAS INTERFERENCE TYPE

Page 205 - Default

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 263 8.3. PNEUMATIC OPERATION Note It is important tha

Page 206 - -20.0 mV 0.0 mV 150.0 mV

Model 9110TH NOx Analyzer Principles of Operation Teledyne Analytical Instruments 264 Figure 8-5: External Pump Pack Finally, the 9110TH/M

Page 207 - 6. INSTRUMENT MAINTENANCE

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 265 8.3.2.1. NO/NOx and AutoZero cycles For the routin

Page 208

Model 9110TH NOx Analyzer Principles of Operation Teledyne Analytical Instruments 266 VACUUM PRESSURE SENSORSAMPLE PRESSURE SENSORO3 FLOW SE

Page 209

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 267 VACUUM PRESSURE SENSORSAMPLE PRESSURE SENSORO3 FLO

Page 210

Model 9110TH NOx Analyzer Principles of Operation Teledyne Analytical Instruments 268 8.3.3.1. Critical Flow Orifice The most important compo

Page 211 - 6.4. MAINTENANCE PROCEDURES

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 269 The following table lists the gas flow rates of th

Page 212

Getting Started Model 9110TH NOx Analyzer Teledyne Analytical Instruments 9 Figure 3-1: 9110TH Front Panel Figure 3-2: Display Screen and

Page 213 - DRYER PARTICULATE FILTER

Model 9110TH NOx Analyzer Principles of Operation Teledyne Analytical Instruments 270 CE Mark safety screw), and should be changed according

Page 214 - 6.4.3.1. Rebuilding the Pump

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 271 8.3.6. O3 GENERATOR The 9110TH/M uses a corona dis

Page 215 - CONVERTER

Model 9110TH NOx Analyzer Principles of Operation Teledyne Analytical Instruments 272 8.3.7. PERMA PURE® DRYER The air supplied to the O3 gen

Page 216

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 273 very large and the dryer’s efficiency is low at fi

Page 217

Model 9110TH NOx Analyzer Principles of Operation Teledyne Analytical Instruments 274 8.3.8. OZONE SUPPLY AIR FILTER The 9110TH/M uses ambien

Page 218

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 275 8.3.10. PNEUMATIC SENSORS Note The 9110TH/M displ

Page 219

Model 9110TH NOx Analyzer Principles of Operation Teledyne Analytical Instruments 276 flow condition (2:1 pressure ratio) through the sample

Page 220

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 277 Figure 8-13: Dilution Manifold Please inquire wi

Page 221 - 7.1. GENERAL TROUBLESHOOTING

Model 9110TH NOx Analyzer Principles of Operation Teledyne Analytical Instruments 278 Figure 8-14: Oxygen Sensor - Principle of Operation 8

Page 222

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 279 8.5. ELECTRONIC OPERATION Figure 8-15 shows a bloc

Page 223

Model 9110TH NOx Analyzer Teledyne Analytical Instruments iii INFORMATION ABOUT THE SPECIFIC CONFIGURATION OF YOUR MODEL 9110T NOX ANALYZER Note

Page 224 - MSG indicates that warning

Model 9110TH NOx Analyzer Getting Started Teledyne Analytical Instruments 10 The front panel liquid crystal display screen includes touch co

Page 225

Model 9110TH NOx Analyzer Principles of Operation Teledyne Analytical Instruments 280 commands to a variety of peripheral devices through the

Page 226

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 281 In the unlikely event that the flash chip should f

Page 227 - 7.1.4. STATUS LED’S

Model 9110TH NOx Analyzer Principles of Operation Teledyne Analytical Instruments 282 8.5.3. PHOTO MULTIPLIER TUBE (PMT) The 9110TH/M uses a

Page 228 - C Connector

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 283 A typical PMT is a vacuum tube containing a variet

Page 229

Model 9110TH NOx Analyzer Principles of Operation Teledyne Analytical Instruments 284 8.5.4. PMT COOLING SYSTEM The performance of the analyz

Page 230 - 7.2. GAS FLOW PROBLEMS

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 285 be adjusted through a potentiometer. These adjust

Page 231

Model 9110TH NOx Analyzer Principles of Operation Teledyne Analytical Instruments 286 8.5.6. PNEUMATIC SENSOR BOARD The flow and pressure sen

Page 232

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 287 Thermistor(s) – Low Temperature Sensing:(e.g. Samp

Page 233

Model 9110TH NOx Analyzer Principles of Operation Teledyne Analytical Instruments 288 Table8-4: Thermocouple Configuration Jumper (JP5) Pin-

Page 234 - PERMAPURE

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 289 Table 8-5: Typical Thermocouple Settings TC TYP

Page 235

Getting Started Model 9110TH NOx Analyzer Teledyne Analytical Instruments 11 Figure 3-3: Display/Touch Control Screen Mapped to Menu Charts

Page 236 - EXHAUST MANIFOLD

Model 9110TH NOx Analyzer Principles of Operation Teledyne Analytical Instruments 290 8.5.8. STATUS LEDS & WATCH DOG CIRCUITRY Thirteen L

Page 237

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 291 8.5.9. MOTHERBOARD This is the largest electronic

Page 238 - 7.2.4. HIGH FLOW

Model 9110TH NOx Analyzer Principles of Operation Teledyne Analytical Instruments 292 PMT TEMPERATURE: This signal is the output of the therm

Page 239 - 7.3. CALIBRATION PROBLEMS

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 293 8.5.10. ANALOG OUTPUTS The analyzer comes equipped

Page 240 - 7.3.2. NO RESPONSE

Model 9110TH NOx Analyzer Principles of Operation Teledyne Analytical Instruments 294 8.6. POWER DISTRIBUTION & CIRCUIT BREAKER The analy

Page 241

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 295 8.7. FRONT PANEL/DISPLAY INTERFACE ELECTRONICS Use

Page 242 - 7.3.6. NON-LINEAR RESPONSE

Model 9110TH NOx Analyzer Principles of Operation Teledyne Analytical Instruments 296 8.8. SOFTWARE OPERATION The instrument’s core module is

Page 243 - SLOPES

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 297 8.8.1. ADAPTIVE FILTER The 9110TH/M NOX analyzer s

Page 244 - 7.4.2. SLOW RESPONSE

Model 9110TH NOx Analyzer Principles of Operation Teledyne Analytical Instruments 298 8.8.3. TEMPERATURE/PRESSURE COMPENSATION (TPC) The soft

Page 245 - 7.4.3. AUTO ZERO WARNINGS

Troubleshooting & Repair Model 9110TH NOx Analyzer Teledyne Analytical Instruments 299 (Equation 9-9) The preset gain parameters are set

Page 246 - 7.5. SUBSYSTEM CHECKOUT

Model 9110TH NOx Analyzer Getting Started Teledyne Analytical Instruments 12 Figure 3-4: 9110TH/M Rear Panel Layout Table 3-2: Rear Panel

Page 248

ESD Primer Model 9110TH NOx Analyzer Teledyne Analytical Instruments 301 9. A PRIMER ON ELECTRO-STATIC DISCHARGE TAI considers the prevention

Page 249

Model 9110TH NOx Analyzer ESD Primer Teledyne Analytical Instruments 302 Table 9-1: Static Generation Voltages for Typical Activities MEANS

Page 250 - 220 VAC /240 VAC

ESD Primer Model 9110TH NOx Analyzer Teledyne Analytical Instruments 303 can occur from a charged conductive object, such as a metallic tool

Page 251

Model 9110TH NOx Analyzer ESD Primer Teledyne Analytical Instruments 304 still trapped and can still build to high enough levels to cause dam

Page 252 - 10 9

ESD Primer Model 9110TH NOx Analyzer Teledyne Analytical Instruments 305  Simply touching a grounded piece of metal is insufficient. While

Page 253 - 7.5.6. I

Model 9110TH NOx Analyzer ESD Primer Teledyne Analytical Instruments 306 1. Attach your anti-ESD wrist strap to ground before doing anything

Page 254 - 7.5.8. LCD DISPLAY MODULE

ESD Primer Model 9110TH NOx Analyzer Teledyne Analytical Instruments 307 9.4.2.3. Transferring Components from Rack to Bench and Back When tr

Page 255 - 7.5.10. MOTHERBOARD

Model 9110TH NOx Analyzer ESD Primer Teledyne Analytical Instruments 308 9.4.2.4. Opening Shipments from Teledyne Packing materials such as

Page 256 - 7.5.10.3. Status Outputs

ESD Primer Model 9110TH NOx Analyzer Teledyne Analytical Instruments 309 3. Place the item in the container. 4. Seal the container. If usi

Page 257 - 7.5.11. CPU

Getting Started Model 9110TH NOx Analyzer Teledyne Analytical Instruments 13 Figure 3-5: 9110TH/M Internal Layout

Page 259 - 7.5.13. PMT SENSOR

Glossary Model 9110TH NOx Analyzer Teledyne Analytical Instruments 311 This page intentionally left blank.

Page 260 - If HVPS reading = 700 VDC

Model 9110TH NOx Analyzer Glossary Teledyne Analytical Instruments 312 10. GLOSSARY Note: Some terms in this glossary may not occur elsewhere

Page 261 - 7.5.17. NO

Glossary Model 9110TH NOx Analyzer Teledyne Analytical Instruments 313 Term Description/Definition include nitrate (NO3), PAN, N2O and other

Page 262

Model 9110TH NOx Analyzer Glossary Teledyne Analytical Instruments 314 Term Description/Definition GFC Gas Filter Correlation I2C bus a cloc

Page 263 - 7.5.19. BOX TEMPERATURE

Glossary Model 9110TH NOx Analyzer Teledyne Analytical Instruments 315 Term Description/Definition handle gases that may react on other surfa

Page 264 - 7.5.20. PMT TEMPERATURE

Model 9110TH NOx Analyzer Getting Started Teledyne Analytical Instruments 14 3.4. ELECTRICAL CONNECTIONS Note To maintain compliance with E

Page 265 - 7.6. REPAIR PROCEDURES

Getting Started Model 9110TH NOx Analyzer Teledyne Analytical Instruments 15 3.4.2. ANALOG INPUTS (OPTION 64) CONNECTIONS The Analog In connec

Page 266 - GENERATOR REPLACEMENT

Model 9110TH NOx Analyzer Getting Started Teledyne Analytical Instruments 16 Table 3-1: Analog Output Data Type Default Settings PARAMETER

Page 267

Getting Started Model 9110TH NOx Analyzer Teledyne Analytical Instruments 17 EMITTER BUS FOR PINS 1-8 STATUS 1 2 3 4

Page 268 - 0 mV is allowed)

Model 9110TH NOx Analyzer Getting Started Teledyne Analytical Instruments 18 3.4.5. CURRENT LOOP ANALOG OUTPUTS (OPT 41) SETUP This option a

Page 269

Getting Started Model 9110TH NOx Analyzer Teledyne Analytical Instruments 19 3.4.5.1. Converting Current Loop Analog Outputs to Standard Volta

Page 270

Model 9110TH NOx Analyzer Teledyne Analytical Instruments iv Power Requirements This Model 9110E is configured to operate from the following

Page 271

Model 9110TH NOx Analyzer Getting Started Teledyne Analytical Instruments 20 3.4.6. CONNECTING THE CONTROL INPUTS Control Inputs are used to

Page 272 - INSTRUMENT

Getting Started Model 9110TH NOx Analyzer Teledyne Analytical Instruments 21 3.4.7. CONNECTING THE ALARM RELAY OPTION (OPT 61) The 9110TH/M ca

Page 273 - Analyzer

Model 9110TH NOx Analyzer Getting Started Teledyne Analytical Instruments 22 Table 3-7: Concentration Alarm Relay Output Operation RELAY FU

Page 274 - 7.9. TECHNICAL ASSISTANCE

Getting Started Model 9110TH NOx Analyzer Teledyne Analytical Instruments 23 3.4.8.3. Connecting to a Multidrop Network The multidrop option i

Page 275

Model 9110TH NOx Analyzer Getting Started Teledyne Analytical Instruments 24 3.5. PNEUMATIC CONNECTIONS Note To prevent dust from getting i

Page 276 - +→+ ONOONO

Getting Started Model 9110TH NOx Analyzer Teledyne Analytical Instruments 25 Even though NO gas in nitrogen could be used as a span gas, the m

Page 277 - MNOMNO ++

Model 9110TH NOx Analyzer Getting Started Teledyne Analytical Instruments 26 3.5.2. PNEUMATIC CONNECTIONS TO 9110TH/M BASIC CONFIGURATION Fi

Page 278 - CatOMxNOyMoxNO

Getting Started Model 9110TH NOx Analyzer Teledyne Analytical Instruments 27 Source of SAMPLE GASRemoved during calibrationInstrumentChassisSA

Page 279 - 8.2.2. OPTICAL FILTER

Model 9110TH NOx Analyzer Getting Started Teledyne Analytical Instruments 28 1. Attach a 1/4" exhaust line between the external pump a

Page 280 - 8.2.3. AUTO ZERO

Getting Started Model 9110TH NOx Analyzer Teledyne Analytical Instruments 29 Figure 3-15: 9110TH Internal Pneumatic Block Diagram - Standar

Page 281 - 8.2.4.1. Direct Interference

Model 9110TH NOx Analyzer Teledyne Analytical Instruments v Valve Options No Valves Internal SS Zero/Span Valves Second Range Span Valve Internal

Page 282 - 8.2.4.3. Light Leaks

Model 9110TH NOx Analyzer Getting Started Teledyne Analytical Instruments 30 VACUUM PRESSURE SENSORSAMPLEPRESSURE SENSORO3 FLOW SENSORFLOW

Page 283 - 8.3. PNEUMATIC OPERATION

Getting Started Model 9110TH NOx Analyzer Teledyne Analytical Instruments 31 3.5.3. CONNECTIONS WITH INTERNAL VALVE OPTIONS INSTALLED If your

Page 284 - 8.3.2. SAMPLE GAS FLOW

Model 9110TH NOx Analyzer Getting Started Teledyne Analytical Instruments 32 3.5.3.1. Ambient Zero/Ambient Span Valves (OPT 50A) The Model 9

Page 285 - and AutoZero cycles

Getting Started Model 9110TH NOx Analyzer Teledyne Analytical Instruments 33 Figure 3-20: 9110TM – Internal Pneumatics with Ambient Zero-Spa

Page 286 - Assemblies

Model 9110TH NOx Analyzer Getting Started Teledyne Analytical Instruments 34 All supply lines should be vented outside of the analyzer’s enc

Page 287 - Control

Getting Started Model 9110TH NOx Analyzer Teledyne Analytical Instruments 35 Table 3-11: Two-Point Span Valve Operating States MODE VALVE CO

Page 288

Model 9110TH NOx Analyzer Getting Started Teledyne Analytical Instruments 36 This page intentionally left blank.

Page 289 - Sensor Option

Teledyne API - Model T200H/T200M Operation Manual Getting Started Teledyne Analytical Instruments 37 Figure 3-21: 9110TH - Internal Pneumatics

Page 290 - 8.3.5. OZONE GAS AIR FLOW

Model 9110TH NOx Analyzer Getting Started Teledyne Analytical Instruments 38 Figure 3-22: 9110TM - Internal Pneumatics for Zero Scrubber/D

Page 291 - 8.3.6. O

Getting Started Model 9110TH NOx Analyzer Teledyne Analytical Instruments 39 3.5.3.3. Internal Flow for O2 Sensor Option 65A Please see Sectio

Page 292 - 8.3.7. PERMA PURE

Model 9110TH NOx Analyzer Teledyne Analytical Instruments vi This page intentionally left blank.

Page 293

Model 9110TH NOx Analyzer Getting Started Teledyne Analytical Instruments 40 Figure 3-24: 9110TM – Internal Pneumatics with O2 Sensor Opti

Page 294 - 8.3.9. OZONE SCRUBBER

Getting Started Model 9110TH NOx Analyzer Teledyne Analytical Instruments 41 3.6. INITIAL OPERATION CAUTION! If the presence of ozone is dete

Page 295 - 8.3.10. PNEUMATIC SENSORS

Model 9110TH NOx Analyzer Getting Started Teledyne Analytical Instruments 42 3.6.3. FUNCTIONAL CHECK After the analyzer’s components have wa

Page 296 - 8.3.11. DILUTION MANIFOLD

Getting Started Model 9110TH NOx Analyzer Teledyne Analytical Instruments 43 3.7. CALIBRATION An initial calibration and functional check shou

Page 297

Model 9110TH NOx Analyzer Getting Started Teledyne Analytical Instruments 44 STEP 1 - Set Units: To select the concentration units of measur

Page 298 - SENSOR

Getting Started Model 9110TH NOx Analyzer Teledyne Analytical Instruments 45 STEP 2 - Dilution Ratio: If the dilution ratio option is enabled

Page 299 - 8.5. ELECTRONIC OPERATION

Model 9110TH NOx Analyzer Getting Started Teledyne Analytical Instruments 46 STEP 3 – Set NOx and NO span gas concentrations : Set the expe

Page 300 - 8.5.1. CPU

Getting Started Model 9110TH NOx Analyzer Teledyne Analytical Instruments 47 STEP 4 – Zero/Span Calibration : To perform the zero/span calibra

Page 301

Model 9110TH NOx Analyzer Getting Started Teledyne Analytical Instruments 48 3.7.2. BASIC O2 SENSOR CALIBRATION PROCEDURE If your instrument

Page 302

Getting Started Model 9110TH NOx Analyzer Teledyne Analytical Instruments 49 3.7.2.2. O2 Calibration Method STEP 1 – Set O2 span gas concentr

Page 303

Model 9110TH NOx Analyzer Safety Messages Teledyne Analytical Instruments vii SAFETY MESSAGES Important safety messages are provided throughou

Page 304 - 8.5.5. PMT PREAMPLIFIER

Model 9110TH NOx Analyzer Getting Started Teledyne Analytical Instruments 50 STEP 2 – Activate O2 sensor stability function To change the st

Page 305 - PMT Preamp PCA

Getting Started Model 9110TH NOx Analyzer Teledyne Analytical Instruments 51 STEP 4 – O2 ZERO/SPAN CALIBRATION : To perform the zero/span cali

Page 306 - 8.5.7. RELAY BOARD

Model 9110TH NOx Analyzer Getting Started Teledyne Analytical Instruments 52 This page intentionally left blank.

Page 307 - J15 and J16

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 53 4. OPERATING INSTRUCTIONS To assist in navigating the anal

Page 308

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 54 The mode field of the front panel display indicates to th

Page 309 - 8.5.7.4. Valve Control

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 55 in one of the DAS channels (Section 4.7) for data analysis

Page 310 - D1 (RED)

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 56 A1:NXCNC1=100 PPM1 A2:NOCNC1=100 PPM1 A3 :N2 CNC1=2 5 P

Page 311 - 8.5.9. MOTHERBOARD

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 57 Table 4-3: List of Warning Messages MESSAGE DEFINITION A

Page 312

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 58 4.3. CALIBRATION MODE 4.3.1. CALIBRATION FUNCTIONS Pressi

Page 313 - 8.5.13. POWER-UP CIRCUIT

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 59 Table 4-5: Secondary Setup Mode Features and Functions MO

Page 314 - RELAY PCA

Model 9110TH NOx Analyzer Safety Messages Teledyne Analytical Instruments viii CONSIGNES DE SÉCURITÉ Des consignes de sécurité importantes

Page 315

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 60 SAMPLE A1:NXCNC1=100PPM NOX=XXX.X

Page 316 - 8.8. SOFTWARE OPERATION

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 61 4.7. SETUP  DAS - USING THE DATA ACQUISITION SYSTEM (DAS

Page 317 - 8.8.1. ADAPTIVE FILTER

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 62 4.7.1. DAS STRUCTURE The DAS is designed around the featu

Page 318

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 63 4.7.1.2. DAS Parameters Data parameters are types of data

Page 319 - 8.8.4. NO

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 64  WARNINGS: Some data may be useful when stored if one o

Page 320

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 65 The default data channels can be used as they are, or they

Page 321

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 66 Table 4-9: 9110TH/M Default DAS Configuration CHANNELS w

Page 322 - DAMAGE AT

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 67 4.7.2.1. Viewing DAS Data and Settings DAS data and settin

Page 323

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 68 4.7.2.2. Editing DAS Data Channels DAS configuration is m

Page 324 - 9.4.1. GENERAL RULES

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 69 To edit the name of a data channel, follow the above key s

Page 325 - MAINTENANCE

Model 9110TH NOx Analyzer Safety Messages Teledyne Analytical Instruments ix This page intentionally left blank.

Page 326 - ESD work bench:

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 70 4.7.2.4. Editing DAS Parameters Data channels can be edit

Page 327

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 71 To configure the parameters for a specific data parameter,

Page 328 - WARNING

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 72 4.7.2.5. Sample Period and Report Period The DAS defines

Page 329

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 73 4.7.2.6. Report Periods in Progress when Instrument Is Pow

Page 330

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 74 To define the REPORT PERIOD, follow the instruction shown

Page 331

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 75 4.7.2.7. Number of Records The DAS is capable of capturing

Page 332 - 10. GLOSSARY

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 76 4.7.2.8. RS-232 Report Function The 9110TH/M DAS can auto

Page 333

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 77 4.7.2.11. Disabling/Enabling Data Channels Data channels c

Page 334

Model 9110TH NOx Analyzer Operating Instructions Teledyne Analytical Instruments 78 4.7.2.12. HOLDOFF Feature The DAS HOLDOFF feature allows

Page 335

Operating Instructions Model 9110TH NOx Analyzer Teledyne Analytical Instruments 79 4.7.3. REMOTE DAS CONFIGURATION Editing channels, paramete