Teledyne 3000TA - General purpose trace oxygen analyzer User Manual

Browse online or download User Manual for Equipment Teledyne 3000TA - General purpose trace oxygen analyzer. Teledyne 3000TA - General purpose trace oxygen analyzer User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 75
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Teledyne Analytical Instruments
Trace Oxygen Analyzer
i
OPERATING INSTRUCTIONS FOR
Model 3000TA
Trace Oxygen Analyzer
P/N M62928
11/24/04
ECO: #03-0126
HIGHLY TOXIC AND OR FLAMMABLE LIQUIDS OR GASES MAY BE PRESENT IN THIS MONITORING
SYSTEM.
PERSONAL PROTECTIVE EQUIPMENT MAY BE REQUIRED WHEN SERVICING THIS SYSTEM.
HAZARDOUS VOLTAGES EXIST ON CERTAIN COMPONENTS INTERNALLY WHICH MAY PERSIST
FOR A TIME EVEN AFTER THE POWER IS TURNED OFF AND DISCONNECTED.
ONLY AUTHORIZED PERSONNEL SHOULD CONDUCT MAINTENANCE AND/OR SERVICING. BEFORE
CONDUCTING ANY MAINTENANCE OR SERVICING CONSULT WITH AUTHORIZED SUPERVISOR/
MANAGER.
DANGER
Page view 0
1 2 3 4 5 6 ... 74 75

Summary of Contents

Page 1 - Model 3000TA

Teledyne Analytical InstrumentsTrace Oxygen AnalyzeriOPERATING INSTRUCTIONS FORModel 3000TATrace Oxygen AnalyzerP/N M6292811/24/04ECO: #03-0126HIGHLY

Page 2 - Model 3000TA

1-41 Introduction Model 3000TATeledyne Analytical InstrumentsData Entry Keys: Six touch-sensitive membrane switches are used toinput data to the

Page 3

1-5Trace Oxygen Analyzer Introduction 1Teledyne Analytical Instruments1.7 Rear Panel (Equipment Interface) The rear panel, shown in Figure 1-2, cont

Page 4

1-61 Introduction Model 3000TATeledyne Analytical Instruments• Calibration Contact To notify external equipment thatinstrument is being calibrate

Page 5

2-1Trace Oxygen Analyzer Operational Theory 2Teledyne Analytical InstrumentsOperational Theory2.1 IntroductionThe analyzer is composed of three subs

Page 6 - COMBUSTIBLE GAS USAGE WARNING

2-22 Operational Theory Model 3000TATeledyne Analytical Instruments(oxygen) comes from outside the device as a constituent of the sample gasbeing

Page 7 - Introduction

2-3Trace Oxygen Analyzer Operational Theory 2Teledyne Analytical InstrumentsAt the top end of the cell is a diffusion membrane of Teflon, whosethick

Page 8 - 1.4 Model Designations

2-42 Operational Theory Model 3000TATeledyne Analytical InstrumentsThe overall reaction for the fuel cell is the SUM of the half reactionsabove,

Page 9

2-5Trace Oxygen Analyzer Operational Theory 2Teledyne Analytical Instruments Figure 2-3. Characteristic Input/Output Curve for a Micro-Fuel Ce

Page 10

2-62 Operational Theory Model 3000TATeledyne Analytical InstrumentsFigure 2-4: Piping Layout and Flow Diagram for Standard ModelFigure 2-5 is t

Page 11

2-7Trace Oxygen Analyzer Operational Theory 2Teledyne Analytical InstrumentsFigure 2-5: Flow Diagram2.4 Electronics and Signal ProcessingThe Model 3

Page 12

Teledyne Analytical Instruments Model 3000TAiiCopyright © 1999 Teledyne Analytical InstrumentsAll Rights Reserved. No part of this manual may be rep

Page 13 - 2.2 Micro-Fuel Cell Sensor

2-82 Operational Theory Model 3000TATeledyne Analytical InstrumentsThe signal processing electronics including the microprocessor,analog to digit

Page 14 - Figure 2-1: Micro-Fuel Cell

2-9Trace Oxygen Analyzer Operational Theory 2Teledyne Analytical InstrumentsIn the presence of oxygen the cell generates a current. A current tovolt

Page 15

2-102 Operational Theory Model 3000TATeledyne Analytical Instruments

Page 16

Trace Oxygen Analyzer Installation 33-1Teledyne Analytical InstrumentsInstallationInstallation of the Model 3000TA Analyzer includes:1. Unpacking2. M

Page 17 - 2.3 Sample System

3 Installation Model 3000TA3-2Teledyne Analytical InstrumentsFigure 3-1: Front Panel of the Model 3000TAAll operator controls are mounted on the

Page 18

Trace Oxygen Analyzer Installation 33-3Teledyne Analytical InstrumentsFigure 3-3: Rear Panel of the Model 3000TA3.3.1 Gas ConnectionsBefore using th

Page 19 - Figure 2-5: Flow Diagram

3 Installation Model 3000TA3-4Teledyne Analytical InstrumentsThe unit is manufactured with 1/4 inch tube fittings, and 6 mm adaptersare supplied f

Page 20

Trace Oxygen Analyzer Installation 33-5Teledyne Analytical InstrumentsPrimary Input Power: The power cord receptacle and fuse block arelocated in the

Page 21

3 Installation Model 3000TA3-6Teledyne Analytical InstrumentsAlarm Relays: The three alarm-circuit connectors are spring terminalsfor making conne

Page 22

Trace Oxygen Analyzer Installation 33-7Teledyne Analytical InstrumentsDigital Remote Cal Inputs: Accept 0 V (off) or 24 V dc (on) inputsfor remote ca

Page 23 - Installation

Teledyne Analytical InstrumentsTrace Oxygen AnalyzeriiiSpecific Model InformationThe instrument for which this manual was supplied may incorporateone

Page 24 - 3.3 Rear Panel Connections

3 Installation Model 3000TA3-8Teledyne Analytical InstrumentsNote: The Remote Probe connector (paragraph 3.3.3) providessignals to ensure that the

Page 25

Trace Oxygen Analyzer Installation 33-9Teledyne Analytical InstrumentsTable 3-2: Required RS-232 OptionsParameter SettingBaud 2400Byte 8 bitsParity n

Page 26

3 Installation Model 3000TA3-10Teledyne Analytical InstrumentsFigure 3-7: FET Series Resistance3.4 Installing the Micro-Fuel CellThe Micro-Fuel Ce

Page 27

Trace Oxygen Analyzer Operation 44-1Teledyne Analytical InstrumentsOperation4.1 IntroductionOnce the analyzer has been installed, it can be configure

Page 28

4 Operation Model 3000TA4-2Teledyne Analytical Instruments4.2 Using the Data Entry and FunctionButtonsData Entry Buttons: The < > arrow butto

Page 29

Trace Oxygen Analyzer Operation 44-3Teledyne Analytical Instruments4.3 The System FunctionThe subfuctions of the System function are described below

Page 30

4 Operation Model 3000TA4-4Teledyne Analytical InstrumentsAfter a password is assigned, the operator must log out toactivate it. Until then, anyone

Page 31

Trace Oxygen Analyzer Operation 44-5Teledyne Analytical InstrumentsIn the first line, TRACK or HOLD should be blinking. The operatorcan toggle betwee

Page 32 - 3.5 Testing the System

4 Operation Model 3000TA4-6Teledyne Analytical InstrumentsUse < > arrows to blink Auto—Cal, and press Enter. A new screen forSpan/Zero set ap

Page 33 - Operation

Trace Oxygen Analyzer Operation 44-7Teledyne Analytical InstrumentsPress System to enter the System mode.TRAK/HLD—CalPSWD Logout MoreUse the < >

Page 34

Teledyne Analytical Instruments Model 3000TAivTable of Contents1 Introduction1.1 Overview ...

Page 35 - 4.3 The System Function

4 Operation Model 3000TA4-8Teledyne Analytical InstrumentsPress Enter to change the password (either the default TBEAI or thepreviously assigned pa

Page 36

Trace Oxygen Analyzer Operation 44-9Teledyne Analytical Instrumentswill immediately switch to the Analyze screen, and you now have access toall instr

Page 37 - PSWD Logout More

4 Operation Model 3000TA4-10Teledyne Analytical InstrumentsPress the System button to start the System function.TRAK/HLD Auto—CalPSWD Logout MoreUs

Page 38

Trace Oxygen Analyzer Operation 44-11Teledyne Analytical InstrumentsTRAK/HLD Auto-CalPSWD Logout More- Use the Right or Left arrow keys and select Mo

Page 39

4 Operation Model 3000TA4-12Teledyne Analytical InstrumentsShut off the gas pressure before connecting it to the analyzer, andbe sure to limit the

Page 40

Trace Oxygen Analyzer Operation 44-13Teledyne Analytical Instruments#### PPM Zero4 Left=### ppm/sThe zeroing process will automatically co

Page 41

4 Operation Model 3000TA4-14Teledyne Analytical InstrumentsCELL FAIL/ ZERO HIGHBefore replacing the cell:a. Check your span gas to make sure it is

Page 42

Trace Oxygen Analyzer Operation 44-15Teledyne Analytical InstrumentsUse the ΔΔΔΔΔ∇ arrow keys to enter the oxygen-concentration mode. Usethe < &g

Page 43 - Show_Negative=NO

4 Operation Model 3000TA4-16Teledyne Analytical InstrumentsOnce the span has begun, the microprocessor samples the output at apredetermined rate. I

Page 44 - Slope=#### ppm/s

Trace Oxygen Analyzer Operation 44-17Teledyne Analytical InstrumentsChapter 3, Installation and/or the Interconnection Diagram included at theback of

Page 45

Teledyne Analytical InstrumentsTrace Oxygen Analyzerv4.3.4 Logout... 4-94.3.5 System

Page 46

4 Operation Model 3000TA4-18Teledyne Analytical InstrumentsIf you are using password protection, you will need to enter yourpassword to access the

Page 47

Trace Oxygen Analyzer Operation 44-19Teledyne Analytical Instruments4.6 The Range FunctionThe Range function allows the operator to program up to th

Page 48 - 4.5 The Alarms Function

4 Operation Model 3000TA4-20Teledyne Analytical InstrumentsNote: The ranges must be increasing from low to high, for example, if range1 is set as 0

Page 49

Trace Oxygen Analyzer Operation 44-21Teledyne Analytical Instrumentslyze function. Alternatively, you can press the Analyze button at any timeto retu

Page 50 - Dft—N Fs—N Ltch—N

4 Operation Model 3000TA4-22Teledyne Analytical InstrumentsRange Voltage (V) Current (mA)LO 0.25 8MED 0.50 12HI 0.75 16CAL (0-25%) 1.00 20IMPORTANT

Page 51 - 4.6 The Range Function

Trace Oxygen Analyzer Maintenance 55-1Teledyne Analytical InstrumentsMaintenance5.1 Routine MaintenanceAside from normal cleaning and checking for l

Page 52 - 4.7 The Analyze Function

5 Maintenance Model 3000TA5-2Teledyne Analytical InstrumentsWARNING: THE SENSOR USED IN THE MODEL 3000TA TRACEOXYGEN ANALYZER USES ELECTROLYTESWH

Page 53 - 4.8 Signal Output

Trace Oxygen Analyzer Maintenance 55-3Teledyne Analytical Instruments1. Remove power to the instrument by unplugging the power cordat the power sour

Page 54

5 Maintenance Model 3000TA5-4Teledyne Analytical Instruments5.2.4 Installing a New Micro-Fuel CellIt is important to minimize the amount of time

Page 55 - Maintenance

Trace Oxygen Analyzer Maintenance 55-5Teledyne Analytical Instruments5.2.5 Cell WarrantyThe Class L-2 Micro-Fuel cell is used in the Model 3000TA.

Page 56 - CELL FAIL/ ZERO HIGH

Teledyne Analytical Instruments Model 3000TAviCOMBUSTIBLE GAS USAGE WARNINGDANGERThis is a general purpose instrument designed for usage in anonhaza

Page 57

5 Maintenance Model 3000TA5-6Teledyne Analytical Instruments2. To change between American and European fuses, remove thesingle retaining screw, f

Page 58

Trace Oxygen Analyzer Maintenance 55-7Teledyne Analytical Instruments5.5 Major Internal ComponentsThe Micro-Fuel cell is accessed by unlatching and

Page 59 - 5.3 Fuse Replacement

5 Maintenance Model 3000TA5-8Teledyne Analytical Instruments5.7 TroubleshootingProblem:Erratic readings of the Oxygen concentration as reported b

Page 60 - American Fuses European Fuses

A-1Trace Oxygen Analyzer AppendixTeledyne Analytical InstrumentsAppendixA-1 SpecificationsPackaging: General Purpose• Flush panel mount (Standard).•

Page 61 - 5.5 Major Internal Components

A-2Appendix Model 3000TATeledyne Analytical InstrumentsAccuracy: ±2% of full scale at constant temperature.±5% of full scale over operating tempera

Page 62 - 5.6 Cleaning

A-3Trace Oxygen Analyzer AppendixTeledyne Analytical InstrumentsA-2 Recommended 2-Year Spare Parts ListQTY.PART NUMBER DESCRIPTION1 C62374 Back Panel

Page 63 - Appendix

A-4Appendix Model 3000TATeledyne Analytical InstrumentsA-3 Drawing ListD-62928 Final Assembly/Outline DrawingA-4 19-inch Relay Rack Panel MountFigu

Page 64 - Appendix Model 3000TA

A-5Trace Oxygen Analyzer AppendixTeledyne Analytical InstrumentsA-53000 SERIES ANALYZERSAPPLICATION NOTES ON RESTRICTORS,PRESSURES, AND FLOW RECOMMEND

Page 65 - TY.PART NUMBER DESCRIPTION

A-6Appendix Model 3000TATeledyne Analytical Instruments The second function that the restriction device provides is a pressuredrop. This device is

Page 66 - A-3 Drawing List

A-7Trace Oxygen Analyzer AppendixTeledyne Analytical InstrumentsCALIBRATION GAS: 3000 series analyzer requirements for units with Auto-Cal options. T

Page 67 - 3000 SERIES ANALYZERS

1-1Trace Oxygen Analyzer Introduction 1Teledyne Analytical InstrumentsIntroduction1.1 OverviewThe Teledyne Analytical Instruments Model 3000TA Trace

Page 68

A-8Appendix Model 3000TATeledyne Analytical Instruments

Page 69

A-9Trace Oxygen Analyzer AppendixTeledyne Analytical InstrumentsA-6 Material Safety Data SheetProduct Name: Micro-Fuel Cells and Super Cells, all clas

Page 70

A-10Appendix Model 3000TATeledyne Analytical InstrumentsFlash Point: na Flammable Limits: na LEL: na UEL: naExtinguishing Media: Use extinguishing

Page 71

A-11Trace Oxygen Analyzer AppendixTeledyne Analytical InstrumentsContact of electrolyte with skin or eyes will cause aburning sensation and/or feel so

Page 72 - Section V – Reactivity Data

A-12Appendix Model 3000TATeledyne Analytical InstrumentsSection VIII – Control MeasuresEye Protection: Chemical splash gogglesHand Protection: Rubb

Page 73 - Protective measures

A-13Trace Oxygen Analyzer AppendixTeledyne Analytical Instruments

Page 74 - Section X – References

1-21 Introduction Model 3000TATeledyne Analytical Instruments• Advanced Micro-Fuel Cell, redesigned for trace analysis, has aone year warranty a

Page 75

1-3Trace Oxygen Analyzer Introduction 1Teledyne Analytical Instruments1.5 Front Panel (Operator Interface)The standard 3000TA is housed in a rugged

Comments to this Manuals

No comments